Morrison Bros. Series 9095C Overfill Prevention Valve

Valve Category:

Overfill Prevention Valves

Valve Subcategory

(for low profile tanks & maximum compatibility)

Manufacturer

Morrison Bros. Co.

Enhanced Vapor Recovery Certified

The 9095C overfill prevention valve is designed to prevent overfilling storage tanks by
providing a positive shut-off during a pressurized fill. The valve installs at the fill port of
a storage tank and can be set to the desired shut-off level by using standard length pipe
nipples. Anodized aluminum construction increase the matrix of fuel compatibility.

Features:

  • Shut-off level can be set to within 1ΒΌ" from the top of the tank
  • Tight fill connection required. Top fill, remote fill, and dry disconnect connections available
  • Installs on a 4" schedule 40 NPT male riser connection
  • Standard drop tubes (Morrison 419) are easily attached with included drop tube adaptor
  • Field adjustable float can be adjusted up to 5" for precise shut-off level
  • Aviation model includes additional float section
  • Integral anti-siphon function
  • Full flow to shut-off point
  • Cushioned shut-off eliminates line shock
  • Integral pressure relief feature allows for safe uncoupling at the completion of the fill operation
  • 5 PSI and 5 GPM minimum flow requirements
  • Typical flow rate is 175 GPM at 10 PSI pressure drop

A mechanical test mechanism is available as an option. The test mechanism allows a
technician to pull on the test line at any time during the filling process to actuate the
float, stop the fill, and verify the valve is working properly.

Construction Details

  • Adaptor... Anodized aluminum
  • Body... Anodized aluminum
  • Float... Nitrophyl-N
  • Plunger and dashpot... Anodized aluminum
  • Upper tube and float guard... E-coated steel
  • Shut-off mechanism... Stainless steel

Certifications & Listings

NFPA 30, 30A, UFC, BOCA,
SBCCI/SFC and PEI RP200.
Florida DEP EQ 356.
CARB VR 402A (some models).

NOTE

For use on clean product only.
Not suitable for motor oil.


Size Maximum Pressure Maximum Viscosity
2" 100 PSI 300 Centistokes


Item Number Valve Size Tank Opening Inlet Size & Type Weight (lbs) Request Quote
Top Fill 9095C-0200 AV 2 4 Valve with 2" male quick disconnect 9.0 Request Quote
9095C-5200 AV 2 4 Valve with 2" dry disconnect adaptor 9.64 Request Quote
9095C-5200AVEVR 2 4 Valve with 2" dry disconnect adaptor 9.64 Request Quote
9095C-AV0200 AV 2 4 Aviation valve with 2" male quick disconnect 9.0 Request Quote
9095C-AV5200 AV 2 4 Aviation valve with 2" dry disconnect adaptor 9.64 Request Quote
9095CA5200AVEVR 2 4 Aviation valve with 2" dry disconnect 9.64 Request Quote
Remote Fill 9095C-3200 AV 2 4 Valve with 2" female threads 12.50 Request Quote
9095C-3200AVEVR 2 4 Valve with 2" female threads 12.50 Request Quote
9095C-AV3200 AV 2 4 Aviation valve with 2" female threads 12.50 Request Quote
9095CA3200AVEVR 2 4 Aviation valve with 2" female threads 12.50 Request Quote
Valve Only 9095C-9100 AV 2 4 Valve less top adaptor, 2" male threads, for low profi le tanks 8.0 Request Quote
9095C-9100AVEVR 2 4 Valve less top adaptor, 2" male threads 8.0 Request Quote
9095C-9200 AV 2 4 Valve less top adaptor, 2" male threads 8.37 Request Quote
9095C-9200AVEVR 2 4 Valve less top adaptor, 2" male threads 8.37 Request Quote
9095C-AV9200 AV 2 4 Aviation valve less top adaptor, 2" male threads 8.37 Request Quote
9095CA9200AVEVR 2 4 Aviation valve less top adaptor, 2" male threads 8.37 Request Quote
9095CTM0100 AM Mechanical test mechanism 1.0 Request Quote
*9095CA models used with fuels with specific gravity less than 0.72.
Morrison Bros. Series 9095C Overfill Prevention Valve
   WARNING: Cancer and
   Reproductive Harm -
   www.P65Warnings.ca.gov