REQUEST A QUOTE
Download JGBHose from Apple App Store Download JGBHose from Google Play

OPW Engineered Systems
Fixed Reach (FXR) Top Loading Arm

Fixed Reach (FXR) Top Loading Arm

Vendor: OPW Engineered Systems

Coupling Type: StandardLine Loading Arms

Description:

Fixed Reach (FXR) Top Loading Arm

Coupling Category:

Top Loading Arms

FXR Order Guide

This simple arm incorporates only three swivel planes of rotation and is designed for use in top-loading installations where the vehicle is located at a fixed distance from the riser pipe. The two swivel planes at the inlet permit both up-and-down and side-to-side movement of the assembly, and the third swivel plane allows the drop pipe to remain vertical.

Features & Benefits:

  • 3000 Series Swivel Joints
    • Simple, Proven Design
    • Carbon Steel/Aluminum Construction
    • Low-Temperature Fluorocarbon Seals
    • Wide Compatibility
  • 790 EZ Adjust Counterbalance
    • Safe, Easy Adjustment
    • Integral, Upward, Downward Travel Stops
  • Available with Loading Valve
    • Safety Closure will automatically close if left unattended
    • Remote Control Linkage allows operator to actuate valve while on truck

Technical Specifications

Materials Ductile Iron/Aluminum
Seals Low-Temp Fluorocarbon
Working Pressure 80 PSI (5.5 Bar)
Test Pressure 120 PSI (8.2 Bar)
Operating Temperature -20ºF to 140ºF (-29ºC to 60ºC)
Up/Down Angular Movement 70º to -20º (from horizontal)
Typical Horizontal Spacing 24" (610 mm)
Typical Vertical Spacing 15" (381 mm)
Typical Reach (radius) 60" to 108" (1,524 mm to 2,743 mm)
Nominal Diameter 3" and 4"
Typical Flow Rates (Velocities < 15 ft/sec (7.5 m/sec)) 300-600 GPM (2,000-3,500 LPM)


Materials of Construction

Inlet Flange 150 ANSI ASTM A105
Inlet Swivel Ductile Iron ASTM A105
Piping Sch 40 Aluminum ASTM B241
Apex/Drop Tube Swivel (p/n 3640FT-0402)
Aluminum ASTM B26 A356 T6


Additional Information

Weld Protection Per the ASME Boiler & Pressure Vessel Code Section IX
Radiograph/X-Ray Per OPW Standard, 5% random/factory lot
Testing All assembled Loading Arms shall be tested to 1.5X the rated design pressure.
Surface Treatments All Carbon Steel/Ductile Iron components to be protected with a 2-part paint process. Aluminum components to be unpainted.
Lubricant OPW 880 High-Performance Synthetic Lubricant
Gasketing KlingerSil C5400
   WARNING: Cancer and
   Reproductive Harm -
   www.P65Warnings.ca.gov