Morrison Bros. 9095 DS Series Overfill Prevention Valve
Vendor: Morrison Bros. Co.
Valve Type(s):
Overfill Prevention Valves
Valve Description:
The 9095DS valve is installed at the fill port of a storage tank.
Designed for use in pressurized fill systems and requires a tight fill
connection. The valve installs in a 2 inch female threaded opening of a
low profile tank requiring a high level shut-off. The valve terminates
the fill when the product reaches the preset level.
Features:
- Designed for fill applications that require a drop tube. (accepts a 1-1/2" male threaded drop tube)
- The valve design allows for full product flow until it reached the shut-off level
- The shut-off height is factory preset and is measured from the bottom of the attachment threads
- Typical flow rate is 26 GPM at 10 PSI pressure drop and 60 GPM at 60 PSI pressure drop
- 10 PSI & 5 GPM is the minimum flow requirement for the valve to operate. The valve will not work in gravity filling applications
- Can be retrofitted to existing tanks
- Immediate and cushioned shutoff…full flow up to within 1-2 seconds of closing and no abrupt kickback or line shock when valve closes
- Dry disconnect…after shut off product is allowed to automatically drain from the highest point so fill nozzle can be removed without spilling
- Simple mechanics…minimum moving parts. Shutoff is activated by basic hydraulic principle with no springs, levers or complicated sequence leading to closure
Construction Details
- Adaptor: Anodized aluminum Part A or Part F
- Body: Anodized aluminum
- Float: Nitrophyl-N
- Plunger and dashpot: Brass
- Upper tube and float guard: Aluminum
- Linkage: Stainless steel
- Shut off mechanism: Anodized aluminum
NOTE:
For use on clean product only. Not suitable for motor oil.Valve Category:
Overfill Prevention Valves
Valve Subcategory
9095DS, 9095DSB
Size | Maximum Pressure | Maximum Viscosity |
2" | 100 PSI | 150 Centistokes |
Fig | Suffix | Size (in) |
Description | Weight | Request Quote |
9095DS | 0200 AV | 2 | AST Overfill Prevention Valve W/Part F Adapter, 2" Shut-Off Height | 8.5 | Request Quote |
9095DS | 0400 AV | 2 | AST Overfill Prevention Valve W/Part F Adapter, 4" Shut-Off Height | 9 | Request Quote |
9095DS | 0600 AV | 2 | AST Overfill Prevention Valve W/Part F Adapter, 6" Shut-Off Height | 9.5 | Request Quote |
9095DS | 2200 AV | 2 | AST Overfill Prevention Valve W/Part A Adapter, 2" Shut-Off Height | 8.5 | Request Quote |
9095DS | 2400 AV | 2 | AST Overfill Prevention Valve W/Part A Adapter, 4" Shut-Off Height | 9 | Request Quote |
9095DS | 2600 AV | 2 | AST Overfill Prevention Valve W/Part A Adapter, 6" Shut-Off Height | 9.5 | Request Quote |
9095DSB | 0200 AV | 2 | AST OPV With BSP Threads, W/Part F Adapter, 2" Shut-Off Height | 8.5 | Request Quote |
9095DSB | 0400 AV | 2 | AST OPV With BSP Threads, W/Part F Adapter, 4" Shut-Off Height | 9 | Request Quote |
9095DSB | 0600 AV | 2 | AST OPV With BSP Threads, W/Part F Adapter, 6" Shut-Off Height | 9.5 | Request Quote |
9095DSB | 2200 AV | 2 | AST OPV With BSP Threads, W/Part A Adapter, 2" Shut-Off Height | 8.5 | Request Quote |
9095DSB | 2400 AV | 2 | AST OPV With BSP Threads, W/Part A Adapter, 4" Shut-Off Height | 9 | Request Quote |
9095DSB | 2600 AV | 2 | AST OPV With BSP Threads, W/Part A Adapter, 6" Shut-Off Height | 9.5 | Request Quote |
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |